Features

Standard Custom Home Building Features

Each custom home built by Beaver Builders is egineered, inspected and tested by qualified engineers to ensure their energy efficiency and structural integrety.  A partial list of home features follows.

ENERGY STAR CERTIFIED
BURGESS CONSTRUCTION CONSULTANTS INSPECTED

Foundation

  • Geo-Tech soil analysis is conducted for each location
  • Professionally engineered foundation design and prepour inspection
    (designed for each home at each location)
  • Engineer inspection on concrete for foundations include slump and break testing
  • Minimum 3000 psi concrete
  • Anchor bolts on exterior walls
  • Offer 10 year structural warranty

Plumbing

  • Vurn PEX water piping
    (copper available upon request)
  • Hot water pipes insulated in slab
  • No water piping joints in slab
  • All gas whenever available
  • In-home fire sprinkler systems available

Electric

  • All copper wiring
  • Home prewired for cable and phone
  • Category 5 wire for phone & computer lines
  • Home prewired for security, upon request

HVAC

  • Engineer designed and load rated for each home
  • Programmable thermostats
  • Units are a minimum rating of 14 SEER
  • Fresh air intakes
  • 4″ media filters
  • Duct blast test on air distribution systems

Framing

  • Modern framing technigues for energy efficiency
  • Wolmonized base plates in contact with foundation
  • 100% of outside wall sheathing is OSB plywood
  • Outside walls wrapped with house wrap
  • Radiant barrier decking on non-conditioned attic spaces
  • Hurricane straps used to tie rafters to outside walls
  • Insulated Concrete Forms ( ICF ) available for increased structural integrety and energy efficiency
  • 3rd party inspections prior to sheetrock

Roofing

  • Shingles nailed (not stapled)
  • 90 # rolled roofing in valleys
  • Metal drip edge around entire perimeter
  • Metal, slate, or other roof coverings available

Cabinets, Trim, Countertops

  • All wood custom cabinets
  • Raised panel doors in kitchens
  • Minimum 3¼ base board in all rooms
  • Large variety of interior and exterior trim options
  • Custom built bullnose shelves in closets
  • Garage trimmed out
  • Variety of countertops including granite, Silestone, tile, concrete, stainless steel etc…

Insulation

  • Homes thermosealed at doors and windows
  • Minimum R-19 in 2×6 exterior walls
  • Minimum R-13 in 2×4 exterior walls
  • Minimum R-38 in attics with R-19 in vaults
  • Foam encapsulation and conditioned attic spaces available

Safe Rooms

  • Built to Federal Emergency Management Agency & Texas Tech University’s Wind Engineering Research Center Specifications
  • Dupont storm room with KEVLAR®
  • ICF concrete storm rooms with steel doors
Be Sociable, Share!